Tekniske data
Cable length:
Side 1
Family construction form:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage DC max.:
Current operating per contact max.:
Industrial communication
Transfer parameters:
Data transmission rate max.:
Industrial communication | Ethernet functionality
duplex:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Mechanical data
Contour for corrugated hose:
Mechanical data | Material data
Coating locking:
Locking material:
Mechanical data | Mounting data
Looking techniques:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
Cable shielding (type):
Cable shielding (coverage):
Banding:
Filler:
wire arrangement:
Mechanical data | Cable
Traversing distance (C-track):
Travel speed (C-track):
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material inner jacket:
Color (inner jacket):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Electrical data | Cable
Loop resistance:
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Characteristic impedance:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Electrical capacity line constant (wire - wire):
Power frequency withstand voltage (wire - jacket):
AC withstand voltage (wire - shield):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
No. of torsion cycles:
Torsion stress:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Handelsinformasjon
Tolltariffnummer:
GTIN:
Pakkestørrelse:
Godkjenninger
Certificates
Certificate
Certificate
Certificate
Certificate
Flytt
RJ45 Push Pull male 0° with cable AIDA RJ45 Push Pull male 0° with cable AIDA
PUR 1x4xAWG22 shielded gn UL/CSA+drag ch. 15m
Vekt: 1.014 kg
Artikkelnummer: 7000-74601-7961500

Kontakt oss for leveringsdato
Flytt
RJ45 Push Pull male 0° with cable RJ45 Push Pull male 0° with cable
PUR AWG22 shielded gn UL/CSA+drag ch. 15m
Vekt: 1.136 kg
Artikkelnummer: 7000-74607-7961500

Kontakt oss for leveringsdato
15 m
15 m
-
RJ45
-
IP65, IP67
60 V
60 V
1,5 A
1,5 A
CAT5, Class D (ISO/IEC 11801:2002), (EN 50173-1)
CAT5, Class D (ISO/IEC 11801)
100 MBit/s
100 MBit/s
Full duplex
-
IP65, IP67
-
inserted, screwed
-
3
3
1 kV
1 kV
I
I
without
without
Nickeled
Nickeled
Zinc die-casting
Zinc die-casting
Push Pull
Push Pull
-25 °C
-40 °C
85 °C
70 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
796
796
green
green
cURus
cURus
1
1
4 wires around Core filler twisted
4 wires around Core filler twisted
copper braid, tinned
copper braid, tinned
85 %
85 %
Fleece, Foil
Fleece, Foil
yes
yes
white, yellow, blue, orange
white, yellow, blue, orange
5 m @ 25 °C
5 m @ 25 °C
3,3 m/s @ 25 °C
3,3 m/s @ 25 °C
69,3 g/m
69,3 g/m
PUR
PUR
89 Shore A
89 Shore A
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
6,7 mm
6,7 mm
± 5 %
± 5 %
FRNC
FRNC
natur
natur
PE
PE
4
4
1,4 mm
1,4 mm
± 5 %
± 5 %
65 Shore D
65 Shore D
lead-free, CFC-free, halogen-free
lead-free, CFC-free, halogen-free
7
7
22 AWG
22 AWG
22 AWG
22 AWG
Stranded copper wire, bare
Stranded copper wire, bare
5000 MΩ × km
5000 MΩ × km
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
4,8 A
4,8 A
100 Ω ± 15 % @ 100 MHz
100 Ω ± 15 % @ 100 MHz
55 Ω/km @ 20 °C
55 Ω/km @ 20 °C
2 kV @ 60 s
2 kV @ 60 s
50000 pF/km
50000 pF/km
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
-40 °C
-40 °C
80 °C
80 °C
-30 °C
-30 °C
70 °C
70 °C
-
-
-
-
-
-
-
-
-
-
IEC 60332-2-2 | UL 1581 § 1090 | UL 1581 § 1100 FT2
IEC 60332-2-2 | UL 1581 § 1090 | UL 1581 § 1100 FT2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
5 x Outer diameter
5 x Outer diameter
12 x Outer diameter
12 x Outer diameter
1 Mio. 25 °C
1 Mio. 25 °C
± 180 °/m
± 180 °/m
27061801
27061801
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
EC002599
EC002599
85444210
85444210
4048879406956
4065909000595
1
1
* pluss MVA og frakt