Har du spørsmål angående produktene våre? Ekspertene våre hjelper deg gjerne videre! Ring oss +47 32 1790-80

Produkt sammeligning for 2 produkter

 Vidresend
Artikkel
Tekniske data
Cable length:
Side 1
Tightening torque:
Family construction form:
Thread:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Family construction form:
Thread:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage DC:
Operating voltage DC min.:
Operating voltage DC max.:
Current operating per contact max.:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Mechanical data | Material data
Color housing:
Material housing:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Cable data
Cable
Cable identification:
Cable Type:
wire arrangement:
Approval (cable):
Cable weight [g/m]:
Material wire:
Resistor (core):
Single wire Ø (core):
Construction (core):
Diameter (core):
AWG:
Material wire isolation:
Material property wire insulation:
Shore hardness wire isolation:
Wire-Ø incl. isolation:
Color/numbering of wires:
Stranding combination:
Shield:
Material jacket:
Material property (jacket):
Shore hardness jacket:
Outer-Ø (jacket):
Color jacket:
chemical resistance:
Nominal voltage:
Test voltage:
Current load capacity:
Temperature range (fixed):
Temperature range (mobile):
Bending radius (fixed):
Bending radius (dynamic):
No. of bending cycles (C-track):
Travel speed (C-track):
Acceleration (C-track):
General data | Cable
Cable identification:
Cable Type:
Function cable:
Printing color of wire insulation:
Printing spacing of wire insulation:
Jacket Color:
Type of Certificate:
STOOW style jacket:
Structure | Cable
Stranding cable total:
Amount stranding:
Stranding:
Stranding factor min.:
Stranding factor max.:
Amount stranding (type 2):
Stranding (type 2):
Stranding factor min. (type 2):
Stranding factor max. (type 2):
Amount stranding (type 3):
Stranding (type 3):
Stranding factor min. (type 3):
Stranding factor max. (type 3):
Amount stranding (type 4):
Stranding (type 4):
Stranding factor min. (type 4):
Stranding factor max. (type 4):
Amount stranding (type 5):
Stranding (type 5):
Stranding factor min. (type 5):
Stranding factor max. (type 5):
Cable shielding (type):
Cable shielding (coverage):
Pair shielding (type):
Banding:
Filler:
Drain wire (type):
Drain wire (cross-section):
wire arrangement:
Mechanical data | Cable
Cable length max.:
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material inner jacket:
Color (inner jacket):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Material properties wire insulation:
Ingredient freeness wire insulation:
Printing color of wire insulation:
Printing spacing of wire insulation:
Resistances wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Drain wire (cross-section):
Material conductor wire:
Conductor type (wire):
Electrical function wire:
Material wire insulation (Data):
Outer diameter wire insulation (Data):
Tolerance outer diameter wire insulation (data):
Shore hardness wire insulation (Data) :
Material properties wire insulation (Data):
Ingredient freeness wire insulation (Data):
Resistances wire insulation (Data):
Printing color wire insulation (data):
Printing spacing wire insulation (Data):
Amount wires (Data):
Amount strands wire (Data):
Diameter of single wires (Data):
Conductor crosssection wire (Data):
Material conductor wire (Data):
Wire conductor type (Data):
Electrical function wire (data):
Material wire insulation (Power):
Outer diameter wire insulation (Power):
Tolerance outer diameter wire insulation (Power):
Shore hardness wire insulation (Power):
Material properties wire insulation (Power):
Ingredient freeness wire insulation (Power):
Resistances wire insulation (Power):
Printing colour wire insulation (Power):
Printing spacing wire insulation (Power):
Amount wires (Power):
Amount strands wire (Power):
Diameter of single wires (Power):
Wire conductor cross section (Power):
Material conductor wire (Power):
Conductor type wire (Power):
Electrical function wire (Power):
Electrical data | Cable
Nominal voltage AC max.:
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Current load capacity min. Wire (Data):
Current carrying capacity min. wire (Power):
Electrical function wire:
Electrical function wire (data):
Characteristic impedance:
Electrical resistance line constant wire:
Electrical resistance coating wire (Power):
Electrical resistance coating wire (Data):
AC withstand voltage (wire - wire):
Electric inductivity line constant:
Electric capacitance:
Electrical capacity line constant (wire - wire):
Electrical capacity line constant (wire - shield):
Power frequency withstand voltage (wire - jacket):
AC withstand voltage (wire - shield):
Transmission frequency range:
Isolation resistance:
Loop resistance:
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Storage temperature min.:
Storage temperature max.:
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (installation):
Bending radius (fixed):
Bending radius (dynamic):
No. of bending cycles (C-track):
Traversing distance (C-track):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Handelsinformasjon
Pakkestørrelse:
Tolltariffnummer:
GTIN:
Godkjenninger
Certificates
Certificate
Certificate
Certificate
Certificate
Flytt
M12 male 0° A-cod. / MSUD valve plug A-18mm M12 male 0° A-cod. / MSUD valve plug A-18mm
PUR 5x0.34 gy UL/CSA 2.5m
Vekt: 0.166 kg
Artikkelnummer: 7000-40921-2250250

ikke tilgjengelig
Flytt
M12 male 0° A-cod. / MSUD valve plug A-18mm M12 male 0° A-cod. / MSUD valve plug A-18mm
PUR 5x0.34 ye UL/CSA 3m
Vekt: 0.193 kg
Artikkelnummer: 7000-40921-0250300

ikke tilgjengelig
2,5 m
3 m
0,4 Nm
0,4 Nm
MSUD
MSUD
M3
M3
IP67
IP67
0,6 Nm
0,6 Nm
M12
M12
M12 x 1
M12 x 1
SW13
SW13
IP67
IP67
24 V
24 V
18 V
18 V
30 V
30 V
4 A
4 A
inserted, screwed
inserted, screwed
3
3
0,8 kV
0,8 kV
black
black
Plastic
Plastic
inserted, screwed
inserted, screwed
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
DIN EN 61076-2-101 (M12); DIN EN 175301-803 (Ventilstecker)
DIN EN 61076-2-101 (M12); DIN EN 175301-803 (Ventilstecker)
225
-
2 (PUR/PVC)
-
-
(white, blue), (black, red)
UL (AWM-Style 20549/1731), CSA; CE conform
-
54,78 g
-
Cu wire, bare
-
max. 57 Ω/km (20 °C)
-
0.1 mm
-
42× 0.1 mm (multi-strand wire class 6)
-
5× 0.34 mm²
-
similar to AWG 22
-
PVC
-
CFC-, cadmium-, silicone- and lead-free
-
43 ±5 D
-
1.25 mm ±5%
-
br, bk, bl, wh, gnye longitudinally striped
-
5 wires twisted around central filler
-
no
-
PUR/PVC
-
CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant
-
80 ±5 A (PVC-under jacket); 85 ±5 A (PUR-jacket)
-
5.0 mm ±5%
-
gray
-
good resistance to oil, gasoline and chemicals
-
UL 300 V AC
-
2000 V AC
-
to DIN VDE 0298-4
-
-30...+80 °C
-
-5...+80 °C
-
10× outer Ø
-
15× outer Ø
-
max. 2 Mio. (25 °C)
-
max. 3.3 m/s
-
max. 5 m/s²
-
-
834
-
-
-
-
-
-
-
-
-
blue
-
cURus
-
-
-
-
-
1
-
2 wires twisted
-
-
-
-
-
1
-
2 Stranded joints twisted
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
copper braid, tinned
-
65 %
-
-
-
Foil
-
-
-
-
-
22 AWG
-
(white, blue), (black, red)
-
-
-
63,12 g/m
-
PUR
-
90 ± 5 Shore A
-
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
6,9 mm
-
± 5 %
-
-
-
-
-
PE
-
2
-
2,1 mm
-
± 5 %
-
64 ± 5 Shore D
-
-
-
lead-free, CFC-free, halogen-free
-
-
-
-
-
-
-
19
-
24 AWG
-
24 AWG
-
22 AWG
-
copper stranded wire, tinned
-
-
-
Data
-
PE
-
1,5 mm
-
± 53 %
-
-
-
-
-
lead-free, CFC-free, halogen-free
-
-
-
-
-
-
-
2
-
19
-
22 AWG
-
22 AWG
-
copper stranded wire, tinned
-
-
-
Power
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
300 V
-
-
-
-
-
to DIN VDE 0298-4
-
4,5 A
-
6 A
-
-
-
Data
-
Power
-
120 Ω ± 10 % @ 1 MHz
-
78 Ω/km
-
-
-
54 Ω/km
-
2 kV @ 60 s
-
-
-
40000 pF/km
-
-
-
-
-
-
-
2 kV @ 60 s
-
-
-
-
-
-
-
-40 °C
-
80 °C
-
-30 °C
-
70 °C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
-
Good, application-related testing
-
Good, application-related testing
-
Good, application-related testing | DIN EN 60811-404
-
x Outer diameter
-
6 x Outer diameter
-
10 x Outer diameter
-
1 Mio.
-
5 m
-
3 m/s
-
2 Mio.
-
± 30 °/m
-
35 cycles/min
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27060312
27060312
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
1
1
85444290
85444290
4048879150743
4048879344050
* pluss MVA og frakt