Har du spørsmål angående produktene våre? Ekspertene våre hjelper deg gjerne videre! Ring oss +47 32 1790-80

Produkt sammeligning for 2 produkter

 Vidresend
Artikkel
Tekniske data
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Coding:
Material:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage DC:
Operating voltage DC min.:
Operating voltage DC max.:
Operating voltage DC max. (UL-listed):
Current operating per contact max.:
Electrical data | Input
Input voltage AC:
Input voltage AC min.:
Input voltage AC max.:
Input voltage DC:
Input voltage DC min.:
Input voltage DC max.:
Input current:
Electrical data | Output
Utilization category AC-15 (EN IEC 60947-5-1):
Utilization category DC-13 (EN IEC 60947-5-1):
Additional condition switching frequency:
Switching frequency max.:
Power rating AC max.:
Power rating DC max.:
Switching voltage AC max.:
Switching voltage DC max.:
Switching current DC:
Switching current max.:
Switching capacity AC-12 (EN IEC 60947-5-1):
Diagnostics
Status indication LED:
Status indication LED:
Installation | Connection
Mounting set:
Device protection
Condition lifetime:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Rated surge voltage:
Electrical lifetime:
Device protection | Mechanical
Mechanical endurance:
Mechanical data
Drop-out time max.:
Response time max.:
Bounce time max.:
Mechanical data | Material data
Coating locking:
Coating of fitting:
Material contact:
Locking material:
Material screw connection:
Mechanical data | Mounting data
Mounting method:
Mounting method:
Suitable for mounting type:
Height:
Width:
Depth:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature min.:
Operating temperature max.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Cable data
Cable
wire arrangement:
General data | Cable
Cable identification:
Cable Type:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
No. of bending cycles (C-track):
Traversing distance (C-track):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Connection data
Connection type 1
Connection:
Family construction form:
Gender:
No. of poles:
PIN 1:
PIN 2:
PIN 3:
Connection type 2
Connection:
Family construction form:
Gender:
No. of poles:
PIN 1:
PIN 2:
PIN 3:
Connection type 3
Connection:
Family construction form:
Gender:
No. of poles:
PIN 1:
PIN 2:
PIN 3:
PIN 4:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Handelsinformasjon
GTIN:
Tolltariffnummer:
Pakkestørrelse:
Godkjenninger
Certificates
Certificate
Certificate
Certificate
Certificate
Certificate
Flytt
RM-21/230V AC OUTPUT RELAY RM-21/230V AC OUTPUT RELAY
IN: 230 VAC/DC - OUT: 250 VAC/DC / 5 A
Vekt: 0.124 kg
Artikkelnummer: 51412

Kontakt oss for leveringsdato
Flytt
M12 female 90° A-cod. with cable LED M12 female 90° A-cod. with cable LED
PUR 4x0.34 bk UL/CSA+robot+drag ch. 20m
Vekt: 0.725 kg
Artikkelnummer: 7000-12421-6542000

Er produsert til deg med høy prioritet
-
20 m
-
0,6 Nm
-
inserted, screwed
-
M12
-
M12 x 1
-
10 mm
-
A
-
PUR
-
SW13
-
IP65, IP66K, IP67
-
24 V
-
18 V
-
30 V
-
30 V
-
4 A
230 V
-
195 V
-
250 V
-
230 V
-
195 V
-
250 V
-
10 mA
-
3 A @ 24 V, 3 A @ 110 V, 3 A @ 230 V
-
1,5 A @ 24 V, 0,3 A @ 110 V, 0,15 A @ 230 V
-
with load
-
0,1 Hz
-
1250 VA
-
240 W
-
250 V
-
250 V
-
100 mA
-
8 A
-
8 A (24/110/230 V AC)
-
-
green, white, yellow
red
-
-
M12 x 1
load-dependent
-
-
inserted, screwed
-
3
-
0,8 kV
-
I
4 kV
-
20000000 Cycles
-
20000000 Cycles
-
10 ms
-
10 ms
-
2 ms
-
-
safe-cover coated
-
nickel plated
Ag Sn O2
-
-
Zinc die-casting
-
Zinc die-casting
-
inserted, screwed, Shaking protection
geschnappt
-
Mounting rail TH35, G32, (EN 60715)
-
75 mm
-
22,5 mm
-
102 mm
-
-
-25 °C
-20 °C
-
-
85 °C
50 °C
-
-
depending on cable quality
-
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
-
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
-
DIN EN 61076-2-101 (M12)
-
brown, black, blue, white
-
654
-
5
-
black
-
cURus
-
1
-
4 wires twisted
-
brown, black, blue, white
-
36,3 g/m
-
PUR
-
58 ± 3 Shore D
-
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
4,7 mm
-
± 5 %
-
PP
-
4
-
1,25 mm
-
± 5 %
-
74 ± 3 Shore D
-
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
42
-
0,1 mm
-
0,34 mm²
-
Stranded copper wire, bare
-
strand class 6
-
300 V
-
to DIN VDE 0298-4
-
4,8 A
-
60 Ω/km @ 20 °C
-
2,5 kV @ 60 s
-
2,5 kV @ 60 s
-
-40 °C
-
80 °C / 90 °C @ 10000 h Operation
-
-25 °C
-
80 °C / 90 °C @ 10000 h Operation
-
-
-
-
-
-
-
-
-
DIN EN ISO 4892-2 A
-
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
-
Good, application-related testing
-
Good, application-related testing
-
Good, application-related testing | DIN EN 60811-404
-
5 x Outer diameter
-
10 x Outer diameter
-
10 Mio. @ 25 °C
-
5 m @ 25 °C | horizontal
-
3,3 m/s @ 25 °C
-
1 Mio.
-
± 360 °/m
-
35 cycles/min
Screw terminals SK
-
terminal
-
female
-
3
-
22
-
21
-
24
-
Screw terminals SK
-
terminal
-
female
-
4
-
11
-
14
-
12
-
Screw terminals SK
-
terminal
-
female
-
4
-
A 11
-
A 12
-
A 21
-
A 22
-
27371001
27279218
27371601
27279218
27371601
27279218
27371601
27279218
27371601
27060311
27371601
27060311
27371601
27060311
27371601
27060311
EC001437
EC001855
4048879027632
4048879309738
85364900
85444290
1
1
-
-
-
* pluss MVA og frakt